Explorer 9 + Probe CP-18 — explorer plus periodontal pocket-depth probe.

Login to see price

Not Available For Sale


  • Brand
  • Choose Your Handle

This combination does not exist.

Brand: ErgoDenta

ErgoDenta
ErgoDenta

Designed in Denmark — ergonomic dental hand instruments built for comfortable, efficient daily clinical work across diagnostics, restoration, periodontics, surgery and sterilisation.

Explore the ErgoDenta range →

Website Product Category :
Diagnostics , Explorer & Probes


The Explorer 9 + Probe CP-18 is a double-ended diagnostic instrument — an explorer to detect caries, calculus and restoration margins on one end, and a periodontal probe to measure pocket depth on the other.

  • Two diagnostic jobs in one instrument — detect and measure
  • Explorer tip for caries, calculus and margin detection
  • Marked periodontal probe for pocket-depth and recession readings
  • Fewer instrument swaps during examinations
Sizes / figuresCP-18
Handle optionsErgoX® · ErgoX® Plus · ErgoSteel S · ErgoSteel SP · ErgoSteel SS
SterilisationFully autoclavable
SuppliedNon-sterile
Brand lineErgoDenta

Reprocessing Instructions

Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.