Half Impression Tray – Non-Perforated – Right
4591-1
Non-perforated half tray for partial dental impressions, right side.
Website Product Category :
Impression TraysTags :
The Half Impression Tray – Non-Perforated – Right is a non-perforated stainless steel half tray for taking partial dental impressions on the right side. The smooth tray wall is intended for impression materials that bond to the tray without mechanical perforation, and its narrower footprint suits quadrant-level work. The tray is reusable and fully autoclavable for ongoing clinical use, and the stainless steel body holds its shape through repeated sterilisation. The handle is shaped to allow controlled seating and lifting of the tray during the impression. Use the right-side version for single-quadrant impression work on the corresponding side of the mouth.
Key features
- Stainless steel construction
- Reusable and fully autoclavable
- Rim-Lock retention
- Non-perforated smooth tray wall
- Half tray, right side
- Suited to single-quadrant partial impressions
Specifications
- Article #: 4591-1
- Side: Right
- Design: Non-perforated
- Design: Non-perforated half tray
- Material: Stainless steel
- Sterilisation: Fully autoclavable
Reprocessing Instructions
Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.