Castroviejo Needle Holder Curved,18cm,TC needle holder for grasping and driving suture needles.

Login to see price

Not Available For Sale


This combination does not exist.



The Castroviejo Needle Holder Curved,18cm,TC is a needle holder for grasping and driving suture needles precisely during oral surgery.

  • Secure jaws grip the needle without slipping
  • Locking ratchet for controlled suturing
  • Reusable and fully autoclavable
  • Suitable for suture sizes 5/0 – 8/0
TypeNeedle holder
Length18cm
Suture sizes5/0 – 8/0
SterilisationFully autoclavable
SuppliedNon-sterile
Brand lineErgoDenta

Suture & Needle Holder Guide

Golden rule: match the needle holder jaw to the needle size. Heavy needles damage fine tungsten carbide (TC) inserts; fine needles slip in heavy jaws. This product's recommended suture sizes are listed in the Description tab.
Needle holder Suture sizes Best for
Mayo-Hegar2/0 – 4/0Heavy sutures, tissue under tension
Mathieu / Mathieu Olsen3/0 – 5/0Fast palm-grip suturing, extractions
Lichtenberg3/0 – 5/0Classic dental pattern, long reach
Crile-Wood3/0 – 6/0Versatile all-rounder
Crile Ryde / Fine Swedish4/0 – 6/0Periodontal & implant suturing
Castroviejo Micro5/0 – 8/0Microsurgery, grafts, esthetic zone
Grip the needle correctly
Clamp about two-thirds from the tip — never at the tip or the swage.
Protect the TC jaws
Never clamp suture thread in the jaws — it frays the thread and wears the insert pattern.
Approximate, don't strangulate
Wound edges should just touch; blanching means the suture is too tight.
Read the full Dental Suture Guide →

Reprocessing Instructions

Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.