Lower Molars, Right | Standard Extraction Forcep | ErgoDenta
Fig. 22K Molars, Lower Jaw | Junior Extraction Forceps | ErgoDenta
Fig. 22K Molars, Lower Jaw | Junior Extraction Forceps | ErgoDenta
Login to see price
Lower Molars, Left | Standard Extraction Forcep | ErgoDenta
Lower Molars, Left | Standard Extraction Forcep | ErgoDenta
Login to see price

Lower Molars, Right | Standard Extraction Forcep | ErgoDenta

5005-23
https://ergodenta.dk/web/image/product.template/10890/image_1920?unique=3fadd83

Standard Extraction Forcep for lower molars, right.

Login to see price

Not Available For Sale


  • Brand
  • Choose Your Handle

This combination does not exist.

Brand: ErgoDenta
Choose Your Handle: English Pattern

ErgoDenta
ErgoDenta

Designed in Denmark — ergonomic dental hand instruments built for comfortable, efficient daily clinical work across diagnostics, restoration, periodontics, surgery and sterilisation.

Explore the ErgoDenta range →

Website Product Category :
Standard Forceps


The Standard Extraction Forcep (Lower Molars, Right) grasps, luxates and removes lower molars, right from the alveolar socket. Serrated beaks give a secure, non-slip grip.

  • Anatomically shaped beaks adapt to lower molars, right
  • Serrated beaks for a secure hold
  • Balanced handle for controlled extraction force
FigureFig. 23
ForLower Molars, Right
BeaksSerrated
SterilisationFully autoclavable
SuppliedNon-sterile
Brand lineErgoDenta

Reprocessing Instructions

Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.