Classic Surgery Kit
Sinuslift Kit
Sinuslift Kit
Login to see price
5, 180x86x26mm, Purple | ErgoTray
5, 180x86x26mm, Purple | ErgoTray
Login to see price

Classic Surgery Kit

9922
https://ergodenta.dk/web/image/product.template/22441/image_1920?unique=5a05761

Classic Surgery Kit · 16 instruments in tray + instrument rack.

Login to see price

Not Available For Sale


This combination does not exist.


Website Product Category :
Surgery , Surgery Kits


Classic Surgery Kit by Dr. Iman — sixteen instruments for efficient everyday surgical workflows. A practical, clinically-tested kit organised in a sterilisation tray and instrument rack.

What's inside

  • 2547 SP — Filling Remover, 1.5–0.5 mm
  • 3007-4C — Goldman Fox, Curved, 13 cm, Black, Super-cut, TC
  • 1310 SP — Explorer 23 + Probe CP 12
  • 7102 SP — Miller 21, 3.0 mm
  • 3629-1AD — College Tweezer, Diamond Tip, 15 cm
  • 3209-2S — Fine Swedish Needle Holder, Straight, 15 cm, TC
  • 1450 SP — ErgoSteel Plus Mirror handle
  • 3801-1G — Micro Surgical Tweezer, Straight, 1–2, 15 cm
  • 1504F — Front-Surface Mouth Mirror, No. 4, 22 mm
  • 5594 — Bowl, 50×60×15 mm
  • 7156 SP — Nordberg Molt, 4 mm–7 mm
  • 5584 — Perforated Instrument Tray, 284×183×17 mm
  • 3437-1S — Hemostatic Forceps, Straight, 12 cm
  • 5555 — Instrument Holder, 280 mm
  • 4014 — Langenbeck Retractor, 42×11 mm, 22 cm
  • 7158 SP — Glickmann, 4 mm–4 mm

16 instruments in tray + instrument rack

Specifications

  • Article #: 9922
  • Contents: 16 instruments in tray + instrument rack
  • Material: Surgical stainless steel
  • Sterilization: Autoclavable, all standard cycles

Reprocessing Instructions

Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.