Surgery Kit by DND
9919
Crile-Wood Needle Holder, Straight, 15cm, TC
Iris Scissor, Curved, 15cm, TC
Meriam Tweezer, Serrated, Fig 1., 16cm
Adson Tweezer, 1x2, 12cm
Obwegeser Internal Retractor, 55 x 12 mm, 22cm
M23 Sickle Scaler
Explorer 23 + Probe CP 12
ErgoSteel, Mirror handle
#4 Front-Surface Mirror Ø22mm (1 pc)
Lucas 87, 3.5mm
Nordberg Molt 4mm-7mm
Glickmann, 4mm-4mm
Bone Scrapper, 3mm-5mm
Scalpel handle no. 3 (Round)
Rochester Pean Forceps, Curved, 13.5cm
Bowl 50*60*11mm
Sinus Lift Instrument, 4mm-4mm
Removable lid, Sterilization cassette for 20, Blue
Reprocessing Instructions
Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use.
Step 1
Pre-Cleaning
Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing.
Step 2
Automated Cleaning
Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry.
Step 3
Inspect & Maintain
Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant.
Step 4
Package
Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly.
Step 5
Sterilize
Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators.
Step 6
Store
Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.